Customization: | Available |
---|---|
Measurement Method: | Absolute Encoding |
Minimum Reading: | 1”/5”selectable |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ET-02/ET-02L | ET-05/ET-05L | ET-10 | |
TELESCOPE | |||
image | erect | ||
magnification | 30X | ||
effective aperture | 45mm | ||
resovling power | 3" | ||
field of view | 1°30' | ||
minimum focusing distance | 1.4m | ||
stadia ratio | 100 | ||
stadia constant | 0 | ||
tube length | 157mm | ||
ANGLE MEASUREMENT | |||
measurement method | Absolute Encoding | ||
diameter of circle (VHz) | 79mm | ||
minimum reading | 1"/5"selectable | ||
accuracy | 2" | 5" | 10" |
detection method: hor. ver. |
dual dual |
dual dual |
dual dual |
DISPLAY | |||
(LCD) display type | 2 sides, LCD | ||
LASER POINTER | |||
laser range | 100m | ||
SENSITIVITY OF VIAL | |||
plate vial | 30"/2mm | ||
circular vial | 8'/2mm | ||
COMPENSATION | |||
system | liquid-electric detection | plate vial | |
working range | ±3' | ||
accuracy | 1" | 30"/2mm | |
OPTICAL PLUMMET | |||
image | erect | ||
magnification | 3X | ||
focusing range | 0.5m ~ ∞ | ||
field of view | 5° | ||
PHISICAL CHARACTERISTICS | |||
laser pointer | ET-02L: yes | ET-05L: yes | NO |
operating temperature | -20ºC ~ 45ºC | ||
internal power supply | Rechargeable Ni-H battery / AA battery | ||
voltage | 6VDC | ||
operating time | 10 hours | ||
dimension | L145 X H318 X W179mm | ||
weight | 5.2kg |
1.All products are inspected before shipment, if you are not satisfactory with the purchase, you can exchange the items in one week, and you must contact us within 24 hour of receipt of the products.
2.The shipping charges are not refundable and the customer should be responsible for all the charges of return and reshipping.
3.For our majority products (Auto level, Theodolite, Total Station) we are offing 1 year warranty;
4.For small issues like missing or damaged part, key board, please send us the photos, we will send the required part and related instructions to you for free;
5. For big issues in one year warranty like EDX board, main board issue. We could only ask you to send the instrument back to us. Normally we will have it fixed in 10 working days and send back to you. You and we shall take care of the corresponding shipping cost on each side. For big issues out of one year warranty, the customer should be responsible for all the cost.